Approximate Humidity Levels Per Setting:
“Drier” 20% to 30% Relative Humidity
“Normal” 45% to 55% Relative Humidity
(Recommended)
“Humid” 80% to 90% Relative Humidity
Thedehumidierwillrununtiltherelativehumidity(RH)isreducedtothehumiditycontroldialsetting.
Quality humidity meters are available from the factory and are recommended to accurately monitor humidity
levels. Refer to the options and accessories table in this document.
6.2 Fan Switch
Turning the impeller switch to “FAN ON” will cause the unit’s internal impeller to run continuously, whether the
unit is dehumidifying or not. This function is desirable if the unit is used for air circulation.
Turning the fan switch to “FAN AUTO” will cause the unit’s internal blower to run only while the unit is
dehumidifying.
7. Maintenance
CAUTION! NOTE: Do not operate the unit without the lter or with a less effective
lter. The heat exchange coils inside the unit could become clogged and require
disassembly to clean.
7.1 Air Filter
TheQuest110DualshipswithastandardMERV8pleatedfabriclter.Thisshouldbecheckedeverysix
months.Thepleatedfabricltercangenerallybevacuumedcleanseveraltimesbeforeneedingreplacement.
Operatingtheunitwithadirtylterwillreducedehumidiercapacityandefciencyandmaycausethe
compressortocycleonandoffunnecessarily.Replacementlterscanbeorderedfromyourdealerorbycalling
1-800-533-7533.