CAUTION! The Quest 110 Dual requires a drain trap. Creating a drain trap allows a small amount
ofwatertobuildupinthetrapareaoftheclearhose.Thispreventsairfrombackowingthroughthehose
andintothedehumidier;essentiallycausingtheunittobackowwateroutofthecornersofthemachine.
Positionthetrapinthehoseapproximately8”-10”fromthedehumidierandmakesurethehighestpointof
thetrapisstillatleast2”belowtheblackdrainportadapteronthedehumidier.Ifthehighestpointofthe
trapisabovethedrainport,waterwillbackowintothedehumidier.Checkthehoseregularlytoensure
water is draining properly.
Several trap options include:
Usecaretokeepthehoseasattotheooraspossible
afteryourtrapisinplace.Besurethehoseisnotkinkedorotherwiserestrictedsowatercanpassthrough
thehosefreely.Improperinstallationofthedrainhosemayresultinwaterleakage.
IftheQuest110Dualislocatedtoofarfromtheoordrainandtheprovidedhosedoesnotreach,youmay
use a 1/2” PVC rigid pipe to extend the drain. Rigid PVC tubing is readily available from your local hardware
store. Be sure the extension is at a down-word slope to the drain.
Anoptionalcondensatepumpkitmaybeinstalledifliftisrequiredtoremovecondensate.Toorder,contact
your local dealer or visit our website at www.QuestProtect.com. You may also reach us by phone at (800)
533-7533.
5. Ducting
5.1 Duct Kit (P/N 4033039)
Afactorydesignedoutletductkitcanbepurchasedtoaccept10”ductingtobothoutletsoftheQuest110
Dual. Contact your dealer or order online.
6. Operation
6.1 Humidity Control Adjustment
The humidity control is an adjustable switch that closes when the relative humidity of the air in which it is
located rises to the dial set point. It opens when the RH drops 4 to 6% below the set point.
Pretzel Loop
Floor Bend PVC Trap
Standard Loop
PVC materials available from
your local hardware store.