WARNING! Before installing the dehumidier in the manner described in section
4.1D (Fig. 4), call the factory for specic instructions if backdraft devices (i.e. hot waters
heaters) are present in the space to be dehumidied.
4.1D In A Remote Area, Ducted Return Only (g. 4)
WhentheQuestDualislocatedinaroomseparatefromthemainareatobedehumidied,itmaybe
desirable to dehumidify and/or slightly pressurize that room. Pressurization assures that open combustion
devices do not backdraft. This can be prevented by installing a duct from the humid room to the Quest Dual
inletandbyallowingtheQuestDualtodischargedehumidiedairintotheroominwhichit’slocated.An
adequateairowpathmustexistbetweenthetworoomsforthismethodtoworkproperly.
WARNING!
4.2 Electrical Requirements
The Quest Dual plugs into a common grounded outlet on a 110-120 VAC 15-Amp circuit. Use of a ground
fault circuit interrupter (GFCI) protected circuit is recommended. The unit should not be used in areas prone
toooding.
Front View
Input of
Humid Air
Output of Dehumidified Air