Mercury 4
Multimode Fan Speed Controller
Easy Guide
VANCOUVER, WASHINGTON U.S.A.
®
®
www.titancontrols.net
For technical assistance call us at
1-888-80-Titan or 1-888-808-4826.
Step 1
Plug into 120VAC outlet
Place the sensor at desired location
Connect the fan in the front panel outlet
For multiple fan application, use a power bar.
Step 2
Turn top knob fully clockwise into <<Set Idle>> zone
Step 3
Select MODE and IDLE SPEED (Idle speed means minimum speed)
INSTRUCTIONS – REV. A
Designed for single phase 120 Vac induction motor fans
up to 750 Watts
Step 4
Set temperature
(knob shall no longer
point at the <<Set Idle>> zone)
Light sensor
(photocell)
Temperature
sensor
120 Volts/6 Amps/60Hz
D
a
y
/
N
i
g
h
t
M
u
l
t
i
-
F
u
n
c
t
i
o
n
F
a
n
S
p
e
e
d
C
o
n
t
r
o
l
l
e
r
M
e
r
c
u
r
y
4
P
h
o
t
o
c
e
l
l
120 Volts/6 Amps/60Hz
D
a
y
/
N
i
g
h
t
M
u
l
t
i
-
F
u
n
c
t
i
o
n
F
a
n
S
p
e
e
d
C
o
n
t
r
o
l
l
e
r
M
e
r
c
u
r
y
4
P
h
o
t
o
c
e
l
l
120 Volts/6 Amps/60Hz
D
a
y
/
N
i
g
h
t
M
u
lt
i
-
F
u
n
c
t
i
o
n
F
a
n
S
p
e
e
d
C
o
n
t
r
o
l
l
e
r
M
e
r
c
u
r
y
4
P
h
o
t
o
c
e
l
l
Turn knob between <<->> and <<+>> signs in
UPPER section to set Idle speed.
DAY: fan runs between idle speed you set and full speed.
NIGHT: operates same as day time but fan will stop if a
low temperature condition is met (*).
UPPER MODE
LOWER MODE
MIDDLE MODE
Turn knob between <<->> and <<+>> signs in MIDDLE section to
set Idle speed.
DAY and NIGHT: fan runs between idle speed you set and full
speed; low temperature will NOT stop the fan.
Turn knob between <<->> and <<+>> signs in LOWER section
to set Idle speed.
DAY and NIGHT: fan runs between idle speed you set and full
speed but will stop if a low temperature condition is met (*).
(*) The low temperature condition is met when actual tempera-
ture is colder than (SETPOINT -10°F)
(eg.: With a SETPOINT of 75°F, a low temp condition is met
when actual temp drops below 65°F).
Bottom knob value is LATCHED when
top knob leaves the <<Set Idle>> zone,
therefore rotating bottom knob has no
effect during normal operation.